Cold end recovery currents and quench currents of Nb 3Sn multifilamentary wires with different amounts of stabilizing copper have been measured in magnetic fields between 8 and 11.5 T. The effective heat flux, Q e , at the recovery current in the Nb 3Sn wire was > 0.58 W cm −2 at 10 T. Also, the heat flux showed a clear dependence on the amount of stabilizing copper in the wire and on the magnetic field strength. The behaviour of the heat flux was in good agreement with the equal area theorem of Maddock et al. 16
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.