Abstract

A comprehensive forced degradation study for bromopride was carried out in accordance with International Conference on Harmonization (ICH) recommendations followed by the identification and prospecting of the major degradation products. The analytical quality by design (AQbD) concepts were used to develop a stability-indicating method for bromopride and five organic impurities quantitation by ultra-high performance liquid chromatography with UV detection (UHPLC-UV). Two screenings and one optimization design were performed, including a Monte Carlo simulation to assess the Method Operable Design Region (MODR). The AQbD approach provided a high degree of method understanding in a very short period of time, less than two weeks, and the validated MODR provided information on robust analytical conditions contributing to the assignment of suitable control strategies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.