Abstract
We developed novel stability-indicating HPLC method for simultaneous estimation of 14 impurities in excedrin tablet, a formulation with a combination of acetaminophen, aspirin, and caffeine. In addition, a new impurity that was generated through degradation of aspirin at high temperatures during the accelerated stability conditions was positively identified and confirmed, using liquid chromatography-mass spectrometry technique. The HPLC method was optimized using the Inertsustain C18 , 250 × 4.6 mm, 5.0 μm column, employing simple gradient method. Forced degradation studies were performed under acidic, basic, oxidative and thermal conditions to prove the scope and stability-indicating the nature of the method. The optimized method was validated as per the International Conference on Harmonization guidelines. The HPLC method showed linearity from LOQ concentration to 21 μg mL-1 . Precision and intermediate precision values were <5% RSD. The validated HPLC method is currently applied for the routine testing of excedrin tablet formulations in quality control laboratories.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.