Abstract
Recent efforts have demonstrated that radiomic features extracted from the peritumoral region, the area surrounding the tumor parenchyma, have clinical utility in various cancer types. However, as like any radiomic features, peritumoral features could also be unstable and/or nonreproducible. Hence, the purpose of this study was to assess the stability and reproducibility of computed tomography (CT) radiomic features extracted from the peritumoral regions of lung lesions where stability was defined as the consistency of a feature by different segmentations, and reproducibility was defined as the consistency of a feature to different image acquisitions. Stability was measured utilizing the "moist run" dataset and reproducibility was measured utilizing the Reference Image Database to Evaluate Therapy Response test-retest dataset. Peritumoral radiomic features were extracted from incremental distances of 3-12mm outside the tumor segmentation. A total of 264 statistical, histogram, and texture radiomic features were assessed from the selected peritumoral region-of-interests (ROIs). All features (except wavelet texture features) were extracted using standardized algorithms defined by the Image Biomarker Standardisation Initiative. Stability and reproducibility of features were assessed using the concordance correlation coefficient. The clinical utility of stable and reproducible peritumoral features was tested in three previously published lung cancer datasets using overall survival as the endpoint. Features found to be stable and reproducible, regardless of the peritumoral distances, included statistical, histogram, and a subset of texture features suggesting that these features are less affected by changes (e.g., size or shape) of the peritumoral region due to different segmentations and image acquisitions. The stability and reproducibility of Laws and wavelet texture features were inconsistent across all peritumoral distances. The analyses also revealed that a subset of features were consistently stable irrespective of the initial parameters (e.g., seed point) for a given segmentation algorithm. No significant differences were found in stability for features that were extracted from ROIs bounded by a lung parenchyma mask versus ROIs that were not bounded by a lung parenchyma mask (i.e., peritumoral regions that extended outside of lung parenchyma). After testing the clinical utility of peritumoral features, stable and reproducible features were shown to be more likely to create repeatable models than unstable and nonreproducible features. This study identified a subset of stable and reproducible CT radiomic features extracted from the peritumoral region of lung lesions. The stable and reproducible features identified in this study could be applied to a feature selection pipeline for CT radiomic analyses. According to our findings, top performing features in survival models were more likely to be stable and reproducible hence, it may be best practice to utilize them to achieve repeatable studies and reduce the chance of overfitting.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.