Abstract

To assess the stability of patient-specific phase shifts between external- and internal-respiratory motion waveforms, the reliability of enhanced external–internal correlation with phase-shift correction, and the feasibility of guiding respiratory-gated radiotherapy (RGRT) over 30 min. In this clinical feasibility investigation, external bellows and internal-navigator waveforms were simultaneously and prospectively acquired along with two four-dimensional magnetic resonance imaging (4DMRI) scans (6–15 m each) with 15–20 m intervals in 10 volunteers. A bellows was placed 5 cm inferior to the xiphoid to monitor abdominal motion, and an MR navigator was used to track the diaphragmatic motion. The mean phase-domain (MPD) method was applied, which combines three individual phase-calculating methods: phase-space oval fitting, principal component analysis, and analytic signal analysis, weighted by the reciprocal of their residual errors (RE) excluding outliers (RE >2σ). The time-domain cross-correlation (TCC) analysis was applied for comparison. Dynamic phase-shift correction was performed based on the phase shift detected on the fly within two 10 s moving datasets. Simulating bellows-triggered gating, the median and 95% confidence interval for the navigator's position at beam-on/beam-off and %harm (percentage of beam-on time outside the safety margin) were calculated. Averaged across all subjects, the mean phase shifts are found indistinguishable (p > .05) between scan 1 (55˚ ± 9˚) and scan 2 (59˚ ± 11˚). Using the MPD method the averaged correlation increases from 0.56 ± 0.22 to 0.85 ± 0.11 for scan 1 and from 0.47 ± 0.30 to 0.84 ± 0.08 for scan 2. The TCC correction results in similar results. After phase-shift correction, the number of cases that were suitable for amplitude gating (with <10%harm) increased from 2 to 17 out of 20 cases. A patient-specific, stable phase-shift between the external and internal motions was observed and corrected using the MPD and TCC methods, producing long-lasting enhanced motion correlation over 30m. Phase-shift correction offers a feasible strategy for improving the accuracy of tumor-motion prediction during RGRT.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call