Abstract

The stability of downflow stationary fixed-film (DSFF) reactors was evaluated under extreme organic shock loads. Reactors could handle five- to sevenfold increases in organic loading and recover to normal performance in a relatively short period of time (usually 24-72 h) during treatment of well-buffered sucrose and acetic acid wastewater at 27 and 35 degrees C. Overloading was characterized by elevated volatile-acid concentrations, decreased reactor pH, and excess biofilm sloughing. Reactors could not cope with extreme organic shocks during treatment of poorly buffered sucrose wastewater. The pH of the mixed liquor was observed to be a more important factor than the volatile-acid concentration in determining whether DSFF reactors would recover in a reasonable period of time.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.