Abstract
The stability and oxygen permeation behavior of the Ce 0.8Sm 0.2O 2− δ –La 0.8Sr 0.2CrO 3− δ dual-phase composite were investigated under a large oxygen gradient with one side of it exposed to air and the other side to CO, CH 4 or H 2 at elevated temperatures. An oxygen permeation flux of 8.6 × 10 −7 mol cm −2 s −1 was obtained with a 1.1 mm thick membrane tube under air/CO gradient at 950 °C, and no decrease in the flux was observed within a period of 110 h. The oxygen flux under air/CO gradient was found to be about twice that under air/CH 4 or air/H 2 gradients, which may be attributed to the higher catalytic activity of the membrane towards the oxidation of CO. The membrane tube remained intact after high temperature operation for over 1000 h, and no significant change in the phase composition and microstructure occurred. The dual-phase composite may satisfy the stability requirement under the stringent membrane reactor conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.