Abstract

This paper presents the findings of a case study of the stability of a tunnel composite liner using the convergence-confinement method (CCM) and a support capacity diagram by means of 2-D numerical analysis. The height of the loose zone and the induced loads exerted on the composite liner from the numerical analysis are compared to the empirical calculation proposed by Terzaghi’s rock load theory. The case study is taken from a recently completed double-track railway tunnel located in Notog district, Central Java, Indonesia. The numerical result shows the loose zone height is 15 m or roughly 1.5B, where B = tunnel width, giving rock load of 32 ton/m2 and composite liner FoS of 2.4. This is within the estimates obtained from Terzaghi’s rock load theory, which amounts to 12-21 m, giving the rock load of 25-46 ton/m2 and corresponding composite liner FoS of 3.1 to 1.7. It is also observed that each supporting element in the composite liner can sustain the induced loads due to excavation, with FoS well beyond 2.0. Compared to the supporting capacity of each supporting element, the loads carried by the steel-sets are significantly lower than those carried by the shotcrete.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.