Abstract

The doubly fed machine (DFM) is presently given an increasing attention in high power variable speed drives and in wind power generation systems, where it exhibits high performances. This has been gained thanks to the stator flux oriented control. Nevertheless, beyond the effect of heating, the robustness of such control strategy is affected by saturation especially the main magnetic one. Accounting for the effect of the magnetizing branch saturation in steady‐state stability analysis, considering the case of a voltage‐controlled DFM and the case of a current‐controlled one, represents the aim of the study. To this end, a numerical procedure based on a combination of the eigenvalue and the fixed point methods has been developed. It has been found that, in both cases, accounting for saturation yields a stabilization effect which is more or less significant depending on the rotor supply parameters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.