Abstract
The analysis of a phase controlled closed loop dc drive is presented. The effect of an important mechanical factor, elasticity of coupling, on drive performance is analyzed. The D-partition technique is used to investigate the interaction of torsional stiffness of motor shaft, converter gain and armature time constant on the system stability. A design procedure to find the value of converter gain that gives minimum settling time is suggested.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.