Abstract

With the large-scale utilization of distributed generation in microgrid, inverter as the connection hub of new energy grid connection, directly affects the operation performance of microgrid. In order to improve the output voltage quality and load capacity of the inverter in the off-grid mode of distributed energy, the stability region of the inverter with load is analyzed by using the impedance analysis method of cascade converter and control theory. The quasi proportional resonant (QPR) double loop control is adopted to realize no static error tracking voltage while increasing bandwidth, and the influence of control parameters on performance is analyzed. At the same time, in order to improve the capacity of inverter with nonlinear load, odd harmonics are introduced into the controller to suppress the influence of low harmonics of load current on output voltage. Finally, the influence of inverter output impedance change, load level, controller parameters and filter parameters on system stability is analyzed through impedance ratio Nyquist curve, which provides corresponding theoretical support and parameter optimization reference for the design of actual system.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call