Abstract

A nonlinearity model including distortion components for sigma-delta (ΣΔ) accelerometer that allows stability analysis is described. Based on this model, closed-loop stability and signal dependent stability are analyzed detailedly. To verify the conclusions, Matlab/Simulink model for a fourth-order ΣΔ accelerometer is designed. The simulation results indicate that high-order system needs a large compensation coefficient, and it will not affect the performance due to the very high low-frequency gain of the loop filter. High-order system is conditionally stable, and stability is affected by the input signal.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.