Abstract

SUMMARYA grid‐connected inverter is indispensable for photovoltaic power generation and smart grid systems, and it must be designed for stable operation. The impedance method based on the Nyquist criterion is often utilized to analyze the stability of grid‐connected inverter systems. The impedance method is based on the eigenvalues of the product of the inverter output admittance and the line impedance matrices in the frequency domain. However, the frequency characteristics have so far been derived only for inverters with analog control systems. A new frequency analysis method for inverters with digital control systems is proposed in this paper. First, a stability analysis example for a three‐phase LCL‐type inverter controlled digitally is shown and the results are compared and validated with those by simulation using a Saber simulator. Finally, they are also compared and validated with experimental results digitally controlled by a DSP‐based system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.