To estimate the effectiveness of intrapartum ST waveform analysis (STAN) versus cardiotocography (CTG) alone in prevention of metabolic acidosis. Meta-analysis of randomized trials comparing intrapartum fetal monitoring utilizing STAN with CTG versus CTG alone. Primary outcome was neonatal metabolic acidosis, defined as umbilical arterial pH <7.05 and base deficit >12 mmol/L. Five randomized trials including 15,303 singletons, vertex, term, or near-term pregnancies met inclusion criteria and were analyzed. Compared with CTG alone, STAN with CTG was associated with similar incidences of metabolic acidosis (0.81% versus 1.12%, relative risk [RR] 0.80; 95% confidence interval [CI] 0.44 to 1.47), perinatal death, neonatal encephalopathy, Apgar score <7 at 5 minutes, admission to neonatal intensive care unit, and cesarean delivery. Operative vaginal delivery (OVD) was lower in the STAN with CTG compared with CTG alone (13.56% versus 15.20%; RR 0.89; 95% CI 0.83 to 0.97). There is no difference in perinatal outcomes between STAN with CTG compared with CTG alone, except for lower rate of OVD.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.