Abstract
The St Georg modular knee replacement has been studied in 59 cases with an observation period ranging from 28 to 73 months. In 47% of the knees both compartments were replaced; five of the six poor results were in this group. These were revised to a hinge arthroplasty or, in one case, to an arthrodesis. Other complications were few and insignificant. There were no infections. We concluded that unicompartmental knee arthroplasty can be recommended when joint involvement is localised to one compartment only. With more generalised joint disease we prefer a semiconstrained total condylar prosthesis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Journal of bone and joint surgery. British volume
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.