Abstract

This paper investigates the sub-synchronous resonance (SSR) phenomenon in a series compensated doubly-fed induction generator (DFIG) based wind farms. A detailed linear state space model of a fixed-series compensated DFIG wind farm is presented for different operating point conditions. The model of the system includes a wind turbine aerodynamics, a 6 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sup> order induction generator, a 3 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">rd</sup> order two-mass shaft system, a 4 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sup> order series compensated transmission line, an 8 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">th</sup> order rotor and generator side converter controllers, and 1 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">st</sup> order DC link model. The 22 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">nd</sup> order system is modeled in Matlab/Simulink, and modal analysis is performed on the modeled DFIG wind farm, and eigenvalues of the system are calculated. The eigenvalue analysis and time-domain simulation results show that SSR can potentially occur in the fixed-series compensated DFIG-based wind farm even at realistic levels of series compensation. The fixed-series capacitor is replaced with a gate-controlled series capacitor (GCSC), which is a series flexible ac transmission system (FACTS) device composed of a pair of gate-commutated switches in parallel with a capacitor that enables one to control impedance and power flow of transmission lines, for series compensation and SSR damping. The root-locus analysis is employed to design a SSR damping controller (SSRDC) for the GCSC. It is shown than a well-designed SSRDC for the GCSC can alleviate the SSR in DFIG-based wind farms. The IEEE first benchmark model adapted with a DFIG-based wind farm is employed as a case study.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.