Abstract
A pulse-charged coaxial transmission line test stand was developed to evaluate the loss and saturation characteristics of the magnetic core material Vitroperm 500Z under square-pulse excitation (SPE) conditions. The test stand was developed to generate a 100 kV square pulse that was discharged into the primary winding of a Vitroperm magnetic core load. The magnetization rates achieved ranged from 5 to $50~T/\mu s$ , and saturation times ranged from 40 to 100 ns. The design of the SPE test stand is discussed, and experimental results for the Vitroperm core material are presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.