Abstract

Spuriously low values of plasma propranolol concentrations resulted when one commercial brand of collection tube was used. The mechanism of this effect was established and was due to the presence of the stopper containing substances that reduced plasma propranolol binding and resulted in a redistribution of the drug in whole blood so that more was present in the cells and less in the plasma. A similar phenomenon was noted some years ago when a needle for intravenous infusion was used as an indwelling cannula. Th mechanism in this case could not be established as in the interim the phenomenon was no longer detectable. Although it was established that these findings do not apply to all drugs, the data suggest that collection methods should be routinely checked at intervals unless separate venipuncture and all glass collection tubes are used.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.