Abstract

Biotin (vitamin B7) is a water-soluble vitamin used as a co-enzyme for carboxylases essential for human metabolism. The high affinity to streptavidin makes biotin an important substance in immunoassays. Excessive biotin intake due to over-the counter supplements has become problematic because of the effects on laboratory test results. There have been no reports of biotin-induced thyroid immunoassay interference in Korea. We report three patients with papillary thyroid cancer who showed false thyrotoxicosis on follow-up laboratory examinations with a literature review. The patients’ medical history should be thoroughly questioned and patients should be informed to curtail consuming biotin before laboratory tests to avoid assay interference. Non-biotinylated assays can be considered if it is impossible to withhold the supplements. These methods will prevent physicians from making incorrect decisions that could result in an inappropriate treatment for their patients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.