Abstract

Spontaneous rupture of the extensor pollicis longus (EPL) tendon is rare, and spontaneous non-traumatic rupture of both extensor pollicis longus (EPL) and extensor carpi radialis brevis (ECRB) tendons is not reported in literature. Rupture of EPL is usually associated with rheumatoid arthritis, systemic or local steroid injections, fractures of the wrist and repetitive and excessive abnormal motion of the wrist joint. We describe a case of spontaneous rupture of the EPL and ECRB tendons in a female patient, washerwoman by occupation, with no predisposing factor. Exploration of the tendons along with end to end tendon repair was done with excellent results. We describe the possible mechanism of the injury and result after one year follow up.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.