Abstract

When 3 phase induction motors are to be operated from single phase lines, split phase starting is Frequently used. The optimum values of external resistance and reactance for split phase starting may be determined by the method of symmetrical components. In the present paper, equations For determining these values for each of the 2 commonly used split phase starting schemes are derived. The result of calculations based upon this method are shown to compare favorably with experimental data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.