Abstract
BackgroundEvaluation of sufficient adenosine response constitutes a significant challenge in myocardial perfusion imaging (MPI). Splenic switch-off in MPI studies denotes a visually (qualitatively) reduced splenic radiotracer signal during adenosine stress and is considered indicative of sufficient cardiac vasodilation. In this study, we examined semi-quantitative and quantitative approaches to splenic switch-off assessment using [15O]H2O-PET with either summed activity images or calculated parametric splenic blood flow images. MethodsCohort 1: 90 clinical patients undergoing [15O]H2O MPI in whom adenosine response was considered clinically adequate were identified to characterize the corresponding splenic switch-off. Spleen stress/rest-ratio (SSR-ratio) was calculated as spleen stress signal intensity/spleen rest signal intensity on both summed activity and parametric blood flow images.Cohort 2: Twenty-five patients with repeat MPI due to suspected insufficient adenosine response were identified to observe if splenic switch-off on the initial MPI could predict the outcome of the repeat MPI.Cohort 3: Fifty-four patients who were considered adenosine responders on MPI and who had a coronary angiogram (CAG) follow-up within 3 months after MPI served as a separate validation group. ResultsSplenic switch-off was present in most patients with a clinically sufficient adenosine response (Cohort 1), illustrated by both visual (74.4%–86.7%), semi-quantitative (summed activity images) (85.6%), and quantitative (parametric blood flow images) (92.2%) evaluation, which corresponds to the distribution in patients with sufficient adenosine response and follow-up CAG (Cohort 3). In patients suspected of insufficient adenosine response on the initial MPI (Cohort 2), the repeat MPI only yielded different myocardial blood flow (MBF) results if the initial SSR-ratio was >0.90 on splenic parametric blood flow images. Conclusionquantitative splenic switch-off assessment on parametric blood flow images was superior to the semi-quantitative splenic switch-off approach. Patients with a suspected insufficient initial adenosine response and SSR-ratio >0.90 can benefit from a repeat MPI. Thus, the integration of quantitative splenic switch-off using parametric blood flow images in the evaluation of adenosine response may support future clinical decision-making.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.