Abstract

This is an experimental study comparing the suturing time and patency rate of a spiral interrupted suturing technique to those of conventional interrupted and continuous suturing technique in end-to-end as well as end-to-side anastomosis. The spiral interrupted suturing technique requires less time for either end-to-end or end-to-side anastomosis than conventional interrupted suturing technique, and does not result in stenosis as shown in the venous end-to-end anastomosis by continuous suturing technique.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.