Abstract

Background: Cervical interlaminar epidural steroid injection (CIESI) is increasingly used as an interventional treatment for pain originating from the cervical spine. However, serious neurological complications may occur during CIESI because of direct nerve damage following inappropriate needle placement. Case report: A 35-year-old woman presented with posterior neck pain radiating to the left upper arm. Cervical magnetic resonance imaging (MRI) revealed left C6 nerve impingement. CIESI under fluoroscopic guidance was performed at another hospital using the left C5/6 interlaminar approach. Immediately after the procedure, the patient experienced dizziness, decreased blood pressure, motor weakness in the left upper arm, and sensory loss. She visited our emergency department with postdural puncture headache (PDPH) that worsened after the procedure. Post-admission cervical MRI revealed intramedullary T2 high signal intensity and cord swelling from the C4/5 to C6/7 levels; thus, a diagnosis of spinal cord injury was made. The patient’s PDPH spontaneously improved after 48 h. However, despite conservative treatment with steroids, the decrease in abduction of the left fifth finger and loss of sensation in the dorsum of the left hand persisted for up to 6 months after the procedure. As noticed in the follow-up MRI performed 6 months post-procedure, the T2 high signal intensity in the left intramedullary region had decreased compared to that observed previously; however, cord swelling persisted. Furthermore, left C7/8 radiculopathy with acute denervation was confirmed by electromyography performed 6 months after the procedure. Conclusions: Fluoroscopy does not guarantee the prevention of spinal cord penetration during CIESI. Moreover, persistent neurological deficits may occur, particularly due to intrathecal perforation or drug administration during CIESI. Therefore, in accordance with the recommendations of the Multisociety Pain Workgroup, we recommend performing CIESI at the C6/7 or C7/T1 levels, where the epidural space is relatively large, rather than at the C5/6 level or higher.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.