Abstract
The purpose of this study was to evaluate and compare turbo spin echo (TSE) with gradient echo echo-planar imaging (GE-EPI) pulse sequences for functional magnetic resonance imaging (fMRI) of spinal cord activation at 3 T field strength. Healthy volunteers underwent TSE and GE-EPI spinal fMRI. The activation paradigm comprised the temporal alternation of finger motion and rest. Pulse sequences were optimized to obtain sufficient image quality and optimal sensitivity to small T 2 or T 2⁎ relaxation time changes. Spinal cord activation measured by the two pulse sequences was evaluated with respect to spatial distribution of activation, signal sensitivity, and reproducibility. For the GE-EPI sequence, fMRI activation was maximal in the spinal cord segments at the levels of the fifth cervical down to the first thoracic vertebra. For the TSE sequence, fMRI measurements showed no distinct location with maximal activation. Percentage signal change and number of activated voxels were approximately twice as high for GE-EPI compared to TSE fMRI. Reproducibility of the signal changes was much better for GE-EPI than for TSE imaging. To conclude, multi-subjects averaged GE-EPI is more location specific for blood-oxygen-level-dependent (BOLD) activation, more sensitive, and is suggested to be more reproducible than TSE fMRI.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.