Abstract

Spinal cord tolerance data for stereotactic body radiation therapy (SBRT) were extracted from published reports, reviewed, and modelled. For de novo SBRT delivered in 1 to 5 fractions, the following spinal cord point maximum doses (Dmax) are estimated to be associated with a 1% to 5% risk of radiation myelopathy (RM): 12.4 to 14.0 Gy in 1 fraction, 17.0 Gy in 2 fractions, 20.3 Gy in 3 fractions, 23.0 Gy in 4 fractions, and 25.3 Gy in 5 fractions. For reirradiation SBRT delivered in 1 to 5 fractions, reported factors associated with a lower risk of RM include cumulative thecal sac equivalent dose in 2 Gy fractions with an alpha/beta of 2 (EQD22) Dmax ≤70 Gy; SBRT thecal sac EQD22 Dmax ≤25 Gy, thecal sac SBRT EQD22 Dmax to cumulative EQD22 Dmax ratio ≤0.5, and a minimum time interval to reirradiation of ≥5 months. Larger studies containing complete institutional cohorts with dosimetric data of patients treated with spine SBRT, with and without RM, are required to refine RM risk estimates.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.