Abstract

ObjectiveGeneralised spike and wave discharges (SWDs) are pathognomonic EEG signatures for diagnosing absence seizures in patients with Genetic Generalized Epilepsy (GGE). The Genetic Absence Epilepsy Rats from Strasbourg (GAERS) is one of the best-validated animal models of GGE with absence seizures. MethodsWe developed an SWDs detector for both GAERS rodents and GGE patients with absence seizures using a neural network method. We included 192 24-hour EEG sessions recorded from 18 GAERS rats, and 24-hour scalp-EEG data collected from 11 GGE patients. ResultsThe SWDs detection performance on GAERS showed a sensitivity of 98.01% and a false positive (FP) rate of 0.96/hour. The performance on GGE patients showed 100% sensitivity in five patients, while the remaining patients obtained over 98.9% sensitivity. Moderate FP rates were seen in our patients with 2.21/hour average FP. The detector trained within our patient cohort was validated in an independent dataset, TUH EEG Seizure Corpus (TUSZ), that showed 100% sensitivity in 11 of 12 patients and 0.56/hour averaged FP. ConclusionsWe developed a robust SWDs detector that showed high sensitivity and specificity for both GAERS rats and GGE patients. SignificanceThis detector can assist researchers and neurologists with the time-efficient and accurate quantification of SWDs.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call