Abstract
Speech levels were measured in a large number of meetings and meeting rooms to better understand their influence on the speech privacy of closed meeting rooms. The effects of room size and number of occupants on average speech levels, for meetings with and without sound amplification, were investigated. The characteristics of the statistical variations of speech levels were determined in terms of speech levels measured over 10 s intervals at locations inside, but near the periphery of the meeting rooms. A procedure for predicting the probability of speech being audible or intelligible at points outside meeting rooms is proposed. It is based on the statistics of meeting room speech levels, in combination with the sound insulation characteristics of the room and the ambient noise levels at locations outside the room.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.