Abstract

The Steady State Visual Evoked Potential (SSVEP) is a widely used component in BCIs due to its high noise resistance and low equipment requirements. Recently, a novel SSVEP-based paradigm has been introduced for direction detection, in which, unlike the common SSVEP paradigms that use several frequency stimuli, only one flickering stimulus is used and it makes direction detection very challenging. So far, only the CCA method has been used for direction detection using SSVEP component analysis. Since Canonical Correlation Analysis (CCA) has some limitations, a Task-Related Component Analysis (TRCA) based method has been introduced for feature extraction to improve the direction detection performance.Although these methods have been proven efficient, they do not utilize the latent frequency information in the EEG signal. Therefore, the performance of direction detection using SSVEP component analysis is still suboptimal. For further improvement, the TRCA-based algorithm is enhanced by incorporating frequency information and introducing Spectrum-Enhanced TRCA (SE-TRCA). SE-TRCA method can utilize frequency information in conjunction with spatial information by concatenating the EEG signal and its shifted version. Accordingly, the obtained spatio-spectral filters perform as a Finite Impulse Response (FIR) filter.To evaluate the proposed SE-TRCA method, two different sorts of datasets (1) a hybrid BCI dataset (including SSVEP component for direction detection) and (2) a pure benchmark SSVEP dataset (including SSVEP component for frequency detection) have been used. Our experiments showed that the accuracy of direction detection using the proposed SE-TRCA and TRCA approaches compared to CCA-based approach have been increased by 23.35% and 28.24%, respectively. Furthermore, the accuracy of character recognition obtained from integrating P300 and SSVEP components in CCA, TRCA, and SETRCA approaches are 54.01%, 56.02%, and 58.56%, on the hybrid dataset, respectively. The evaluation of the SE-TRCA method on the benchmark SSVEP dataset demonstrates that the SE-TRCA method outperforms both CCA and TRCA, particularly regarding frequency detection accuracy. In this specific dataset, the SE-TRCA method achieved an impressive frequency detection accuracy of 98.19% for a 3-s signal, surpassing the accuracies of TRCA and CCA, which were 97.91% and 90.47%, respectively.These results demonstrated that the TRCA-based approach is more efficient than the CCA approach to extracting spatial filters. Moreover, SE-TRCA, extracting both Spectral and spatial information from the EEG signal, can capture more discriminative features from the SSVEP component and increase the accuracy of classification. The results of this study emphasize the effectiveness of the proposed SE-TRCA approach across different SSVEP paradigms and tasks. These findings provide strong evidence for the method’s ability to generalize well in SSVEP analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.