Abstract

Abstract.A time-resolved diagnostic technique was used to investigate the emission spectra from the plasmas produced by 1.06 μm, 10 ns pulsed laser ablation of semiconductor GaAs. The characteristics of the species in plasma produced at different ambient pressure were analyzed. The full width at half maximum of the spectral line was measured and analyzed according to obtained spectra of the excited atoms; several line broadening factors were estimated according to our experimental conditions and the results indicate that the Stark broadening is the main broadening mechanism. Under the assumption of local thermodynamic equilibrium, the time evolution of electron number density was deduced from the Stark broadening measurements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.