Abstract

A quantum cascade laser (QCL) based system for simultaneous detection of CO and CO2 is developed. The QCL can scan over two neighboring CO (2055.40 cm−1) and CO2 (2055.16 cm−1) lines with a single current scan. The wavelength modulation spectroscopy (f = 20 kHz) is utilized to enhance the signal-to-noise ratio. A white cell with an effective optical path length of 74 m is used. The calibration of the sensor is performed and minimum detection limits of 1.3 ppb (1 × 10−9) for CO and 0.44 ppm (1 × 10−6) for CO2 are achieved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.