A stable plasma column is generated in a quartz tube using a pair of hollow electrodes driven by a sinusoidal power supply of 45 kHz at atmospheric pressure in argon. Two distinct operating modes (low-current and high-current modes) are identified through observing its discharge phenomena, measuring its electrical characteristics, and determining the gas temperatures by spectroscopic diagnosis of Q branch of UV OH spectrum. The electron density in the high-current mode is diagnosed by Stark broadening and is found to be two orders higher than that in low-current mode.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.