Abstract

Cadmium zinc telluride (CZT) pixel detectors show very good spectral and spatial resolution and are suitable for use in compact hard-X-ray sensors operated without cryogenics. One of the most appealing astrophysical applications is their use as focal-plane detectors for multilayer hard-X-ray telescopes operating in the (10-80) keV energy band. This paper reports experimental results obtained from two 16 x 16 pixellated CZT detectors (10 x 10 x 1 mm 3 and 10 x 10 x 2 mm 3 single crystals) with 450 μm pixel operated at room temperature using standard commercial read-out electronics. We have investigated about energy resolution and material properties of both detectors. Both arrays gave similar results showing an energy resolution less than 5% at 59.5 keV and a good material uniformity. The good energy resolution of both detectors demonstrates as the pixellated anode structure reduces (small pixel effect) the incomplete charge collection due to severe hole trapping typically present in CZT crystals. A calibration curve, obtained using three different energies, shows a linear response of the detectors.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.