Abstract

Hybrid linear analysis (HLA), as a recent factor-based multivariate calibration technique, was applied for the spectrophotometric determination of ternary mixtures of pseudoephedrine hydrochloride (PSU), dextromethorphan hydrobromide (DXT), and sodium benzoate (BNZ). The utilized HLA was assisted by a wavelength selection procedure which was based on the calculation of the net analyte signal (NAS) regression plot in any considered wavelengths window for each test sample, in addition to a moving window strategy for searching the region with maximum linearity of NAS regression plot (minimum error indicator (EI)). HLA was applied because it was simpler to adapt to the NAS regression plot methodology, and also used less factors than partial least squares (PLS). An orthogonal array design was applied for formation of calibration and prediction sets in the concentration ranges 0–7500 μmol L −1 for PSU, 0–300 μmol L −1 for DXT, and 0–1400 μmol L −1 for BNZ. The method had the ability to select wavelength regions that minimize the effect of non-linearity of the spectral data, in addition to that of non-modeled interferences. The application of the selected wavelength regions improved the obtained relative standard error of predictions for PSU, DXT, and BNZ, respectively, from 5.24, 8.67, and 5.48% to 2.19, 5.21, and 3.62% (using lower number of factors). To check the ability of the proposed method in selection of linear regions of spectra, a test for detecting non-linear regions of spectral data in multivariate spectroscopic assays was also described. Additives in the commercial syrup samples did not interfere with their determinations. The method was successfully applied for the determination of pseudoephedrine HCl, dextromethorphan HBr, and sodium benzoate in cough suppressant syrup samples.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call