Abstract

Four chemometric methods were applied to simultaneous determination of cilazapril and hydrochlorothiazide in tablets. Classical least-square (CLS), inverse least-square (ILS), principal component regression (PCR) and partial least-squares (PLS) methods do not need any priori graphical treatment of the overlapping spectra of two drugs in a mixture. For all chemometric calibrations a concentration set of the random mixture consisting of the two drugs in 0.1 M HCI and methanol (1:1) was prepared. The absorbance data in the UV–Vis spectra were measured for the 15 wavelength points (from 222 to 276 nm) in the spectral region 210–290 nm considering the intervals of Δ λ=4 nm. The calibration of the investigated methods involves only absorbance and concentration data matrices. The developed calibrations were tested for the synthetic mixtures consisting of two drugs and using the Maple V software the chemometric calculations were performed. The results of the methods were compared each other as well as with HPLC method and a good agreement was found.