Abstract
Spectrophotometric-dual-enzyme-simultaneous assay in one reaction solution (SDESA) is proposed. SDESA requires the following: (a) Enzyme A acts on Substrate A to release Product A bearing the longest difference absorbance peak (λ(A)) much larger than that of Product B (λ(B)) formed by Enzyme B action on Substrate B; λ(B) is close to the longest isoabsorbance wavelength of Product A and Substrate A (λ(0)); (b) absorbance at λ(A) and λ(0) is quantified via swift alternation of detection wavelengths and corrected on the basis of absorbance additivity; (c) inhibition/activation on either enzyme by any substance is eliminated; (d) Enzyme A is quantified via an integration strategy if levels of Substrate A are lower than the Michaelis constant. Chemometrics of SDESA was tested with γ-glutamyltransferase and lactate-dehydrogenase of complicated kinetics. γ-Glutamyltransferase releases p-nitroaniline from γ-glutamyl-p-nitroaniline with λ(0) at 344 nm and λ(A) close to 405 nm, lactate-dehydrogenase consumes reduced nicotinamide dinucleotide bearing λ(B) at 340 nm. Kinetic analysis of reaction curve yielded lactate-dehydrogenase activity free from inhibition by p-nitroaniline; the linear range of initial rates of γ-glutamyltransferase via the integration strategy, and that of lactate-dehydrogenase after interference elimination, was comparable to those by separate assays, respectively; the quantification limit of either enzyme by SDESA at 25-fold higher activity of the other enzyme remained comparable to that by a separate assay. To test potential application, SDESA of alkaline phosphatase (ALP) and β-D-galactosidase as enzyme-linked-immunoabsorbent assay (ELISA) labels were examined. ALP releases 4-nitro-1-naphthol from 4-nitronaphthyl-1-phosphate with λ(0) at 405 nm and λ(A) at 458 nm, β-D-galactosidase releases 4-nitrophenol from β-D-(4-nitrophenyl)-galactoside with λ(B) at 405 nm. No interference from substrates/products made SDESA of β-galactosidase and ALP simple for ELISA of penicillin G and clenbuterol in one well, and the quantification limit of either hapten was comparable to that via a separate assay. Hence, SDESA is promising.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.