Abstract

A simple and highly sensitive spectrophotometric method for the determination of spermine (Spm) was established based on the ternary complex formation reaction of Spm with o-hydroxyhydroquinonephthalein (QP) as a xanthene dye and manganese(II) as a metal ion in the presence of a dispersion agent. The apparent molar absorptivity at 555 nm and the relative standard deviation of the proposed method were 1.4 x 10(5) dm(3) mol(-1) cm(-1) and 0.50% (n = 10), respectively. In the method for flow-injection analysis (FIA), which employs a single-channel flow manifold system, a good linear relationship was observed over the 2 - 20 pg microl(-1) range of Spm by direct injection.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.