Abstract

Four sensitive, selective and precise stability indicating methods for the determination of isopropamide iodide (ISO) and trifluoperazine hydrochloride (TPZ) in their binary mixture and in presence of trifluoperazine oxidative degradate (OXD). Method A is a derivative spectrophotometric one, where ISO was determined by first derivative (D(1)) at 226.4 nm while TPZ was determined by second derivative (D(2)) at 270.2 nm. Method B is the first derivative of the ratio spectra (DD(1)) spectrophotometric method, ISO can be determined by measuring the peak amplitude at 227.4 nm using 5 microg mL(-1) of OXD as a divisor, while TPZ can be determined by measuring the peak amplitude at 249.2 and 261.4 nm using 15 microg mL(-1) of ISO as a divisor. Method C is the isoabsorptive spectrophotometric method. This method allows determination of ISO and TPZ in their binary mixture by measuring total concentration of ISO and TPZ at their isoabsorptive point at lambda(229.8) nm (Aiso1) while TPZ concentration alone can be determined at lambda(max) 311.2 nm, then ISO concentration can be determined by subtraction. On the same basis TPZ can be determined in presence of ISO and OXD, where OXD concentration alone was determined by measuring the peak amplitude at lambda(281.6) and lambda(309.4) nm while total concentration of TPZ and OXD was determined at their isoabsorptive points at (Aiso2 = 270.2 nm), (Aiso3 = 310.6 nm) and (Aiso4 = 331.8 nm) then TPZ concentration was determined by subtraction. Method D is the multivariate calibration techniques [the classical least squares (CLS), principal component regression (PCR) and partial least squares (PLS)], using the information contained in the absorption spectra of ISO, TPZ and OXD mixtures. The selectivity of the proposed methods was checked using laboratory prepared mixtures. The proposed methods have been successfully applied to the analysis of ISO and TPZ in pharmaceutical dosage form without interference from other dosage form additives and the results were statistically compared with the reported method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.