Abstract

A method for the determination of cobalt in steel with 2-(2-thi-azolylazo)-4-methyl-5-(sulfomethylamino) benzoic acid (TAMSMB) is proposed. Iron and manganese were previously removed by the extraction from 7M HCl into methyl isobutyl ketone and with an anion exchange column (Diaion SA # 100), respectively. The results of the analyses of steel samples were in good agreement with those by atomic absorption spectrophotometry. This method was compared with the methods using the highly sensitive reagents for cobalt; 4-(5-chloro-2-pyridylazo)-1,3-diaminobenzene(5-Cl-PADAB), 5-(3,5-dibromo-2-pyridylazo)-2,4-diaminotoluene (3,5-diBr-PADAT), 2-(5-bromo-2-pyridylazo)-5-(diethylamino) phenol(5-Br-PADAP), 2-(2-py-ridylazo)-4-methyl-5-(ethylamino) phenol (EAPAC), 2-(3,5-dibromo-2-pyridylazo)-5-(dimethylamino) benzoic acid (3,5-di-Br-PAMB), 3-(2-thiazolylazo)-2,6-diaminotoluene (2,6-TADAT), and 2-nitroso-5-dimethylaminophenol (Nitroso-DMAP).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.