Abstract

A comprehensive investigation of the spcctrophotometric determination of aluminium with chrome azurol S is described. No heating is required for colour formation, and the method is considerably more reproducible and selective than either the eriochrome cyanine R or aluminon methods. In the presence of suitable masking agents, only Be 2+, Zr 4+, and F-cause serious interference. A molar absorptivity of 21,500 at 567.5 mμ was found for the aluminium-chrome azurol S lake, with a relative standard deviation of ± 0.4% at the 20 μg Al level. Beer's law is obeyed from 0 to 1.2 mg Al/ml.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.