Abstract

Cleaning validation is a major challenge in multi-product pharmaceutical industries. UV spectrophotometric and HPLC methods have been developed and validated for determination of residual amount of Loratadine. Both methods were validated for linearity, range, accuracy, precision, and robustness. The limit of quantification was 1 mg L−1 by UV spectrophotometric method and 0.5 mg L−1 by HPLC method. A spike recovery study was done on a stainless steel (316 grade) plate and specific residual cleaning level (SRCL) was down to 6 μg 25.8 cm−2. Recovery was found to be more than 70%. Both methods were simple, highly sensitive, precise, and accurate, and have potential of being useful for routine quality control.