Abstract
A facile, simple, green and sensitive spectrofluorometric method was developed for determination of the calcimimetic drug cinacalcet hydrochloride. It is used for the treatment of hyperparathyroidism. The drug showed high native fluorescence intensity at 320 nm after excitation at 280 nm. The method was linear over the range of 5.0–400.0 ng ml−1 with excellent correlation (R2 = 0.9999). Limit of detection (LOD) and limit of quantitation (LOQ) values were 1.19 and 3.62 ng ml−1, respectively. The percentage recovery was found to be 100.42% ± 1.39 (n=8). The proposed method was successfully applied for determination of cinacalcet in spiked human plasma samples with % recoveries of (87.23 to 109.69%). Two recent greenness metrics (GAPI and Analytical Eco-Scale) were chosen to prove the eco-friendly nature of the method. Furthermore, the proposed method was successfully applied to dissolution study of commercial cinacalcet tablets. The interference likely to be introduced by some commonly co-administrated drugs such as metoprolol and itraconazole was studied; the tolerance limits were calculated.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.