Abstract

ABSTRACT A new spectrofluorimetric method for determination of germanium traces based on its reaction with 1,2,4-Trihydroxyantraquinone, at an apparent pH 8.8 provided by an ammonia/ammonium chloride buffer, in a 80:20(v/v) ethyleneglycol water medium is proposed. The calibration graph is linear over the range 70–725 ng/ml and features a detection limit of 2.5 ng/ml. The effect of potential major interferences has been investigated and the proposed method was successfully applied to the determination of germanium in synthetic samples and industrial concentrates, after extraction with CCl4, in an 9 M HCl medium.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.