Abstract
To describe the characteristics as well as the sensitivity and specificity of detection of choroidal neovascularization (CNV) on optical coherence tomography angiography (OCTA) using spectral-domain optical coherence tomography. Observational, retrospective study. Seventy-two eyes of 61 subjects (48 eyes of 43 subjects with CNV, 24 eyes of 18 subjects without CNV). Patients imaged using the prototype AngioVue OCTA system (Optovue, Inc, Fremont, CA) between August 2014 and October 2014 at New England Eye Center were assessed. Patients in whom CNV was identified on OCTA were evaluated to define characteristics of CNV on OCTA: size using greatest linear dimension (small, <1 mm; medium, 1-2 mm; large, >2 mm), appearance (well-circumscribed, poorly circumscribed), and presence of subretinal and intraretinal fluid. Concurrently, an overlapping second cohort of patients who underwent same-day OCTA and fluorescein angiography (FA) for suspected CNV was evaluated to estimate sensitivity and specificity of OCTA in detecting CNV using FA as ground truth. Choroidal neovascularization appearance, CNV size, and presence of subretinal and intraretinal fluid. In 48 eyes, CNV was visualized on OCTA. Thirty-one eyes had CNV associated with neovascular age-related macular degeneration. Size of CNV was small in 23% (7/31), medium in 42% (13/31), and large in 35% (11/31). Poorly circumscribed vessels, subretinal fluid, and intraretinal fluid each were seen in 71% (22/31). Seven eyes had CNV associated with central serous chorioretinopathy. Size of CNV was small in 71% (5/7) and large in 29% (2/7). Seventy-one percent (5/7) had well-circumscribed vessels, 86% (6/7) had subretinal fluid, and 14% (1/7) had intraretinal fluid. Thirty eyes with OCTA and same-day FA were evaluated to determine sensitivity and specificity of CNV detection on OCTA. Sensitivity was 50% (4/8) and specificity was 91% (20/22). Using OCTA allows the clinician to visualize CNV noninvasively and may provide a method for identifying and guiding treatment of CNV. The specificity of CNV detection on OCTA compared with FA seems to be high. Future studies with larger sample sizes are needed to elaborate better on the sensitivity and specificity of CNV detection and to illustrate clinical usefulness.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.