Abstract

Retracing behavior of phase matching has been observed in the generation of infrared radiation (1.25–1.85 μm) by both type-I angle-tuned and temperature-tuned difference frequency mixing of a Nd:YAG laser (1064 nm) with its second-harmonic pumped dye laser (570–675 nm) in lithium triborate crystal. Large spectral acceptance of 49 nm at spectral noncritical phase-matching point and angular acceptance of 4.0° at angular noncritical phase-matching point has been obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.