Abstract

The Datex-Ohmeda S/5 Entropy Module (Datex-Ohmeda Division, Instrumentarium Corp., Helsinki, Finland), using time-frequency balanced Spectral Entropy, is a novel tool for monitoring the hypnotic state during anesthesia. The Entropy Module produces two values, State Entropy (SE) and Response Entropy (RE), and in adults, it has been shown to measure reliably the hypnotic effects of various drugs. In children, Spectral Entropy has been only preliminary studied. The authors' aim was to study Spectral Entropy as a marker of hypnotic state during general anesthesia in infants and children. Twenty infants (aged 1 month-1 yr) and 40 children (aged 1-15 yr) were anesthetized for surgery using standardized sevoflurane-nitrous oxide-based anesthesia. The relationships between SE, RE, or Bispectral Index (BIS) and (1) a modified Observer's Assessment of Alertness/Sedation Scale, (2) non-steady state end-tidal concentration of sevoflurane, (3) steady state end-tidal concentration of sevoflurane, and (4) hemodynamic values were calculated using prediction probability, nonlinear regression, and correlation coefficients, as appropriate. The performances of SE, RE, and BIS were compared. The prediction probability values (+/- SEM) of SE, RE, and BIS versus the modified Observer's Assessment of Alertness/Sedation Scale in the induction phase were 0.83 +/- 0.06, 0.88 +/- 0.06, and 0.87 +/- 0.08 for children and 0.76 +/- 0.08,0.79 +/- 0.08, and 0.73 +/- 0.10 for infants; values in the emergence phase were 0.68 +/- 0.05, 0.74 +/- 0.04, and 0.64 +/- 0.05 for children and 0.64 +/- 0.07, 0.69 +/- 0.06, and 0.72 +/- 0.06 for infants, respectively. SE, RE, and BIS values were inversely proportionally related to the end-tidal concentration of sevoflurane for children, but for infants, the correlation was much less clear. No significant correlations were found between SE, RE, or BIS values and the hemodynamic values. Spectral Entropy may be a useful tool for measuring the level of hypnosis in anesthetized children and seems to perform as well as BIS. In infants, the clinical usefulness of both these electroencephalogram-derived methods must be evaluated in further controlled studies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.