The measurement of the photovoltaic (PV) performance with respect to reference conditions requires measuring the performance with respect to a reference spectrum. Procedures were developed in the mid 1980s to correct measurements for errors relating to the spectral irradiance of the light source being different from the standard and the responsivity of the irradiance detector being different from the device under test. In principle, these procedures are exact, but require the measurement of the spectral irradiance of the light source and responsivity of the test device. This is problematic for most facilities that measure module performance. It has been suggested that a polynomial fit of the short-circuit current (I/sub sc/) measured under natural sunlight divided by the total broadband irradiance as a function of air mass provides an accurate spectral correction factor. The polynomial correction factor is normalized to unity at an absolute air mass of 1.5. The polynomial correction factor is compared with the spectral correction factor for a variety of devices at two locations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.