Abstract

This paper presents particle dynamics analysis (PDA) results from three measurement sections of a bipolar charged agglomeration system. The periodogram model and the Burg algorithm for autoregressive spectral estimates were used for the spectral analysis of the unevenly spaced data. The one-dimensional energy spectrum from the Burg algorithm is smoother than that from periodogram model. The spectrum of the main flow velocity with charging is lower than for the case without charging. The results show that the one-dimensional kinetic energy distribution at all frequencies can be well represented by the one-dimensional energy spectrum. The dissipation rate was then obtained from the energy spectrum. The results also show that there is a lower dissipation rate in measurement section 1 with charging than without charging.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.