Abstract

The Z-machine, which is located at Sandia National Laboratories, is currently undergoing refurbishment to increase the output drive current. Due to increased switching voltage requirements, some switch failure modes have been identified with the laser-triggered gas switch design, including envelope surface flashover. In order to improve the performance and lifetime of these switches, a basic understanding of the underlying physics of the failure mechanisms is required. A small-scale experimental setup has been constructed to approximate conditions within the switch. The possible impact of the SF6 volume spark between the switch electrodes on the envelope surface flashover is investigated. Measured optical spectra of the SF6 volume spark over a wide pressure range, from rough vacuum to 40 psig overpressure, are analyzed regarding their potential to contribute to switch failure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.