Abstract
The objective of this study was to analyze apparently discrepant results that arose during the use of an indirect immunofluorescence (IIF) assay using transfected HEp-2 cells to detect anti-SS-A/Ro autoantibodies in human sera. Fourteen sera that had SS-A/Ro antibodies as detected on this commercial substrate, but did not have antibodies to SS-A/Ro as determined by double immunodiffusion (ID) or enzyme-linked immunosorbent assay (ELISA), were studied by immunoprecipitation (IP) of radiolabeled cell extracts and full-length recombinant SS-A/Ro. A multi-antigen strip immunoblotting (IB) assay containing both the 52- and 60-kDa antigens was included in the analysis. We confirmed that 12 of 14 of the sera under study had antibodies to SS-A/Ro protein antigens as determined by at least one other immunoassay. One serum had antibodies to hyRNA but no detectable reactivity with the 52- or 60-kDa antigens. One serum remained negative in all assays for SS-A/Ro autoantibodies.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.